Article original Publié le : 18 aout 2022 Mise à jour le : – Création de raid disk sur un PowerEdge R740xd Se connecter en SSH sur l’iDrac
1 |
$ ssh user@ip_idrac |
1 2 3 |
Warning: Permanently added '10.xx.xx.xx' (ECDSA) to the list of known hosts. Password: racadm>> |
Verifier la présence de volume virtual
1 |
raidracadm>>storage get vdisks |
1 2 3 4 |
ERROR: STOR0104 : No virtual disks are displayed. Check if the server has power, physical disks are available, and virtual disks are created. racadm>> |
Vérifier le nombre de disques
1 |
racadm>>storage get pdisks |
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 |
Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.6:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.7:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.8:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.9:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.10:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.11:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.12:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.13:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.16:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.17:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.18:Enclosure.Internal.0-1:RAID.Integrated.1-1 Disk.Bay.19:Enclosure.Internal.0-1:RAID.Integrated.1-1 |
Ajouter quelques arguments […]